data to be inserted into our database. This example also illustrates how to display the actual hexadecimal (or Hex Dump) content of a numeric field using a callable dump routine. and the Output columns branches. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms. Save my name, email, and website in this browser for the next time I comment. if itab-menge has a value of 2.00, i need to convert that value to ' 200'. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. The type is specified using a specific character selected from the table below. The Source Field is defined as a Zoned-Decimal (or USAGE IS DISPLAY) field with 5 digits and zero decimal positions. Neal, It was explicitly mentioned that "i need to get '0.450' as numeric decimal and do arithmetic on it.". In my previous tip, I introduced aspects to consider when importing data from There is some correction in his code too. I believe, the receiving fields should be 'STRING's too. Explore The Edited for Display format for numeric data strings. comp has different types of ways of storing the in my computer, IBM MAINFRAME, comp is binary and comp3 is packed decimal. The following is a sample of the Dump information produced on a PC with Micro Focus COBOL and Net Express, version 4.0. at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.HandleUserException(Exception e) at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer. The following PROCEDURE DIVISION statement shows how to convert from a ZONED-DECIMAL to a DISPLAY (with SIGN TRAILING SEPARATE) numeric value'. How to convert Python variables into equivalent cobol group variables? This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP" or "USAGE IS BINARY" clause. and select {CR}{LF} as the row delimiter like on the next image. The following is the WORKING-STORAGE definition for the source field. What is the purpose of this D-shaped ring at the base of the tongue on my hiking boots? Just use the assignment statement using "=" (equal) symbol. The light-yellow boxes are SIMOTIME Technologies, Third-party Technologies, decision points or program transitions in the processing logic or program generations. 2) Using the EDIT mask in the JCL. Each byte has two nibbles, and each nibble is indicated by a hexadecimal character. rev2023.3.3.43278. For example://your_job_card//REFMT EXEC PGM=CAWABATC,REGION=4M //STEPLIB DD DSN=your.FM110.CDBILOAD, // DISP=SHR //SYSPRINT DD SYSOUT=* //SYSUDUMP DD SYSOUT=* //SYSUT1 DD DSN=your.CONVERT.INPUT, // DISP=SHR //SYSUT1O DD DSN=your.CONVERT.OUTPUT,// DISP=SHR //SYSIN DD * COPY , INFILE(SYSUT1), OUTFILE(SYSUT1O), REFFILE(your.CONVERT.LIB(REFORMAT)), REPLACEKEY(N) /* Now, when running the job and using the following three records input file:------------------------------------------------------------------------------.@record#01-----------------------------------------------------------------0013579889987FF6666666666666666666666666666666666666666666666666666666666666666600246C953694B0100000000000000000000000000000000000000000000000000000000000000000------------------------------------------------------------------------------record#02-----------------------------------------------------------------0022229889987FF6666666666666666666666666666666666666666666666666666666666666666600222C953694B0200000000000000000000000000000000000000000000000000000000000000000------------------------------------------------------------------------------record#03-----------------------------------------------------------------0033339889987FF6666666666666666666666666666666666666666666666666666666666666666600333C953694B0300000000000000000000000000000000000000000000000000000000000000000------------------------------------------------------------------------------The OUTPUT will contain the numeric data:BROWSE your.CONVERT.OUTPUT Line 0000000000 Col 001 080Command ===> Scroll ===> CSR ********************************* Top of Data **********************************01234567record#01---------------------------------------------------------------02222222record#02---------------------------------------------------------------03333333record#03---------------------------------------------------------------******************************** Bottom of Data ********************************, https://techdocs.broadcom.com/content/broadcom/techdocs/us/en/ca-mainframe-software/devops/ca-filemaster-plus/11-0/using-batch/batch-reference-for-ca-file-master-plus/keywords/keyword-descriptions1.html#concept.dita_de213555aa271bc5db6b08bc7a3ffe71e3bb4084_REFFILE. Will Gnome 43 be included in the upgrades of 22.04 Jammy? Now we are ready to execute the SSIS package and after it completes we can perform The following (NBRCVTJ3.jcl) is a sample of the ZOS oriented JCL needed to run this job in a Mainframe-oriented environment. Which worries me, those should require 10 bytes. Connect and share knowledge within a single location that is structured and easy to search. Why do you believe you want/need floating-point? We specialize in the creation and deployment of business applications using new or existing technologies and services. decimal digits per byte in contrary of the Zoned number representation that holds and view the COBOL source code for this numeric field conversion example. to handle the imported data for columns Category and Balance as binary data. The spaces really do you a favor by causing the SOC7 (Numeric Exception) on the intermediate arithmetic fields. Is the God of a monotheism necessarily omnipotent? Refer to 02 CAUSAL-OUT PIC X(3). I need to be able to write a file that contains binary data. There is nothing in the file to help you identify where it is or if it even exists. For example, the value 15 is stored in two nibbles, using the hexadecimal characters 1 and 5. Browse other questions tagged, Where developers & technologists share private knowledge with coworkers, Reach developers & technologists worldwide. Since both X and Y now occupy the same physical storage, the MOVE can be dropped as the following program and output illustrate: As you can quickly see, the result is probably not what you were hoping for since Y does not contain a human readable formatted number (i.e. copybooks. Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server. In most of the scenarios, your input file has data either in Packed decimal (COMP-3) format or Binary (COMP) format which is not in readable format. This link requires an Internet Connection. . This halves the storage requirements compared to a character, or COBOL "display", field. Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. What do you say? arithmetic on it. Posted: Tue Jun 16, 2009 7:18 pm. Refer to Code: 01 WS-PACKED-DECIMAL PIC S9 (11)V99 COMP-3 VALUE 1542.16. Refer to the Downloads and Links to Similar Pages section of this document for links that provide additional detail about numeric formats. If the definition size matches there shouldn't be any truncation. Refer to the The following (NBRCVTE3.cmd) is a sample of the Windows CMD needed to run this job in a non-Mainframe environment. Browse the Inputs and Outputs Tree by expanding the Flat File Source Output See COBOL Comp-3 Packed Fields. My requirement is: i have fields of type packed decimal in my internal table itab. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. and added one to the 1oth digit and now i have a numeric field as below, IBMMainframes.com is not an official and/or affiliated with IBM. Processors such as the PDP-11 and VAX family of computers, the Intel microprocessors, and much of the communications and networking hardware are little-endian. Not the answer you're looking for? I tried the same, but didnt work. Thanks for contributing an answer to Stack Overflow! Note:A SimoTime License is required for the items to be made available on a local system or server. For example to store an numeric field of value 987 we would required 3 +1 divided by 2 = 2 Hence an Comp-3 field of length 2 bytes can store a value of +999 to -999 as the limit. The standard signs are used: hexadecimal F for positive numbers and hexadecimal D for negative numbers. Disconnect between goals and daily tasksIs it me, or the industry? Unpacked the previous value would look like: This field has 15 (actually 16) digits before the decimal point and 3 after. Back to top. 02 IMPME-OUT PIC S9(13)V9(2) COMP-3. I took assembly and I think all numbers are whole numbers when they are packed the "V" is telling the compiler how to handle the number. The binary strings will be bypassed, the numeric strings will be processed based on their numeric type and the text strings will be converted from EBC to ASC based on a user selected conversion table. Staging Ground Beta 1 Recap, and Reviewers needed for Beta 2. The fewer decimal positions of the result field will be rounded because of the ROUNDED keyword on the ADD statement. See comp-3, above. Site design / logo 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA. The nature of simulating nature: A Q&A with IBM Quantum researcher Dr. Jamie We've added a "Necessary cookies only" option to the cookie consent popup. The OUTPUT will contain the numeric data: BROWSE your.CONVERT.OUTPUT Line 0000000000 Col 001 080. how to convert decimal to Packed decimal/COMP-3, Having trouble unpacking Comp-3 in .Net. Converts a packed number to decimal format. That is a File Master 3.11 Reformat example:------------------ CA File Master Plus -- Dataset Reformat ------------------OPTION ===> BLANK - Update Reformat Control Parms E - Execute Reformat Reformat "FROM": Dataset name ===> 'your.CONVERT.INPUT' Member name ===> Layout DSN ===> 'your.CONVERT.LIB' Layout member ===> CPYBK#O1 Reformat "TO": Dataset name ===> 'your.CONVERT.OUTPUT' Member name ===> Layout DSN ===> 'your.CONVERT.LIB' Layout member ===> CPYBK#N1 Replace Keys ===> N ('Y' to replace duplicate keys in KSDS) Reformat Control Parm: Dataset name ===> 'your.CONVERT.LIB' Member name ===> REFORMAT Execution mode ===> E O = Online S = Submit JCL E = Edit JCL After pressing enter you have to assign the "FROM" fields to the "TO" fields. and COBOLs numeric unpacked or zoned values. 02 FEC-MM PIC X(2). The session will describe three of the popular numeric formats used with COBOL and IBM Mainframe systems. The nature of simulating nature: A Q&A with IBM Quantum researcher Dr. Jamie We've added a "Necessary cookies only" option to the cookie consent popup. SimoTime Technologies was founded in 1987 and is a privately owned company. To subscribe to this RSS feed, copy and paste this URL into your RSS reader. if itab-menge has a value of 2.00, i need to convert that value to ' 200'. Using V6.2 and ARCH(12), the compiler instead uses the vector packed-decimal facility, which accelerates packed and zoned decimal computation by storing intermediate results in vector registers instead . Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. Use the language as it was intended to be used. You need two COBOL data structures, aka. To subscribe to this RSS feed, copy and paste this URL into your RSS reader. For example, I have a 2 character field with value of PR. The fewer decimal positions of the result field will cause the numeric value to be truncated. On the Advanced view we are going to add four columns named Name, Address, Explore OUTREC: Tells SORT what part of input file to be put in output file.PD: Input format in Packed DecimalTO=ZDF: output format to be in all numericsTO=ZD: output format to be in all numerics with an alphabetLENGTH=n: If you want to override the output length, specify as n. Say you have an input file with below packed data as HEX. What video game is Charlie playing in Poker Face S01E07? of them. Lemme know what do you think. Comp-3 stores data in a BCD -- binary coded decimal -- format with the sign after the least significant digit. The following (nbrcvts1.sh) is the Bash Shell Script needed to run this job on a Linux or UNIX System using GnuCOBOL. Example: Data: begin of itab occurs 0, ebeln like ekko-ebeln, ebelp like ekpo-ebelp, menge (15) type p decimals 2, netpr (15) type p decimals 2, end of itab. the COBOL Routine for Example-101 > a hex character to represent a 3-digit insurance plan number (which in. p,m,PD,TO=ZD converts the PD values to ZD values. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. The following is the WORKING-STORAGE definition for the result field. Beginning with version 4.1.1 of COBOL for AIX, during the conversion of a numeric data item to and from a packed-decimal data item, negative zero is no longer converted to positive zero. I HAVE A PACKED DECIMAL FIELD WHICH IS REDEFINED TO A NUMERIC FIELD TO ADD "1" TO ITS TENTH DIGIT. In this tip, I will show you how to Error I'm getting is:Source: Data Flow Task Script Component [166] Description: System.Data.SqlTypes.SqlTruncateException: Numeric arithmetic causes truncation. The following links will require an Internet connect. bPacked (Byte Array): A byte array containing the packed number to be converted to decimal format. This test case will show the process for converting a zoned-decimal-numeric format to a display format. previous tip, SSIS offers us the possibility to extend its functionality by Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? the COBOL Routine for Example-202 It should be V999. The light-red boxes are unique to the SIMOTIME Technologies using a Linux, UNIX or Windows System and COBOL Technologies such as Micro Focus. > our case can be any number from 0 - 199). For more information about the Hex-Dump format refer to the Hexadecimal Dump Format section of this document. Now, on the Script Tab, press the Edit Script button. The three most common mainframe numeric encoding formats are Zoned-Decimal, Packed-Decimal and Binary. handle packed numeric values. Raja, If done correctly, as Gilbert's is, I don't see how you'll S0C7. INTEGER . Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? 02 CONVAL1-OUT PIC S9(13)V9(2) COMP-3. I added a brief description Connect and share knowledge within a single location that is structured and easy to search. The naming of a job script is determined by the Operating System. The following is the WORKING-STORAGE definition for the source field. I need to convert 10-15 different files in the differernt JCL, So I want . Suppose we have the number 40.06. So my advice to you is don't try bend COBOL into something that it is not. You do not need to divide by 1000. and view the COBOL source code for this numeric field conversion example. If a signed number or an explicit decimal is required then a different data type will be required for the result of a conversion process. i.e. SourceForge is an Open Source community resource dedicated to helping open source projects be as successful as possible. The data for the above fields has the following lengths: FIELD-NAME-1: 19 Tab. Is it possible to rotate a window 90 degrees if it has the same length and width? This can be accomplished using SORT. Assuming that the PIC X variable does have nothing but numeric digits, your best bet is a two-step move: move the PIC X to USAGE DISPLAY variable, then move the USAGE DISPLAY variable to the COMP-3 variable. else that would make our package end with an error. Why does my COBOL working storage variable have trailing zeroes? Where developers & technologists share private knowledge with coworkers, Reach developers & technologists worldwide, Interpreting COMP-3 Packed Decimal Fields into numeric values, http://jrecord.cvs.sourceforge.net/viewvc/jrecord/jrecord/src/net/sf/JRecord/Common/Conversion.java?revision=1.2&view=markup, How Intuit democratizes AI development across teams through reusability. Format: label PACK D 1 (L 1 ,B 1 ),D 2 (L 2 ,B 2 ) - Packs the L 2 byte zoned decimal number at D 2 (B 2 ) and stores it as a L 1 byte packed decimal number at D 1 (B 1 ) - The packing process: 1. Yes, for a fixed format define a structure accordingly. . This video shows the format in which numeric data is stored in Zoned decimal (conventional) and packed decimal (COMP-3) format. When a text file contains packed numbers or any other kind of binary 02 FEC-SS PIC X(2). Big Endian - within a multi-byte numeric representation the most significant byte has the lowest address. The following PROCEDURE DIVISION statement shows how to convert from a PACKED to a DISPLAY (with SIGN TRAILING SEPARATE) numeric value. Asusually, I could find out a way to achieve it! We have a team of individuals that understand the broad range of technologies being used in today's environments. This is because, MOVE will work fine, if the hexadecimally stored values are compatible. The Result Field is defined as a Zoned Decimal (or USAGE IS DISPLAY) field with 7 digits and 2 decimal positions. Also, like zoned numbers, packed numbers can have implied decimal This approach will work for unsigned numbers with zero decimal positions. 9(3) is a three digit numeric, and COMP-3 is BCD encoded decimal. Move the 1-byte to the second byte of the 2-byte variable (directly if the 2-byte variable is a group of 2 1-byte . WRITE WORK does not allow format specifications nor edit masks. This following three (3) COBOL programs show the level of detail required to convert a numeric field. The next step is to create a SSIS project and add a Data Flow task, a Flat File to handle the columns as binary data. right! Explore the Numbers Connection for additional information about the structure and processing of numeric data items (or numeric fields). REFFILE. Thanks for contributing an answer to Stack Overflow! FIELD-NAME-3: 9. 02 FILLER PIC X(72). The following PROCEDURE DIVISION statement shows how to convert from a ZONED-DECIMAL to a DISPLAY (or unsigned Zoned-Decimal) numeric value. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies. 18 digits requires 9 bytes, the sign is the low nybble of the low order byte. Long winded but very straight forward. This example illustrates the following functions. For example, an input field read in packed-decimal format has a length of five bytes (as specified on the input or definition specifications). The following is the WORKING-STORAGE definition for the source field. The following PROCEDURE DIVISION statement shows how to convert from a ZONED-DECIMAL to an EDITED numeric value. We reserve the right to make changes without notice at any time. so as i had explained earlier , i moved the packed decimal field to a numeric field and redefined the numeric field each having one digit. This is the "official" BCD packed format of the COBOL standard. In most modern Cobol compilers, you can move a numeric-edited field to a numeric field. COMP-3 occupies INT(N+1/2) by. The Result Field is defined as a Zoned Decimal (or USAGE IS DISPLAY) field with 5 digits and zero decimal positions. Coming to redefining with value field of PIC 9.999 doesnt work because 9.999 is a picture edited type, which will be useful for displaying/output purpose and will still not be able to do the required arithmetic. For eg., i have alphanumeric string 'ABCDEF 0 0.450' and i need to get '0.450' as numeric decimal and do arithmetic on it. It's simply. The following is a sample of the Dump information produced on an IBM Mainframe or Micro Focus Mainframe Express on the PC. Asusually, I could find out a way to achieve it! For example to store an numeric field of value 987 we would required 3 +1 divided by 2 = 2 Hence an Comp-3 field of length 2 bytes can store a value of +999 to -999 as the limit. are Single Byte Unsigned Integer and Numeric with Precision 10 and Scale 2 respectively. The Source Field is defined as a BINARY (or COMP) and the result fields are "USAGE IS DISPLAY" or a numeric edited field. Have you tried to display it with the Edit-Mask (EM=) option? Thanks everyone for the replies..now i know more than one method that wud work. rev2023.3.3.43278. the COBOL Routine for Example-302 1) Simply using the move statement in the cobol prog. 1. If you have read my 02 NUMOPE-OUT PIC X(6). In case of the above question to move the decimal portion of the number need to define an variable which can store only the decimal portion and move the value to that field which would hold just the decimal portion. This section describes the three (3) Windows Command Files that will be used to set the environment and execute the COBOL programs that perform the sample numeric field conversions. packed field = packed field * 10. Required fields are marked *. Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. If doing it that way, you should check that the decimal point is a decimal point, and you should check that your numeric fields are numeric. The following is the WORKING-STORAGE definition for the result field. I included two functions to handle data conversion: Translate and With this you should be answered. much higher than nowadays, it was a wise decision to implement packed numbers at 02 TIPCAM-OUT PIC S9(9)V9(6) COMP-3. Kwebble, UNSTRINGing into some NON-STRING variables didn't work. The following is the WORKING-STORAGE definition for the result field. Using Kolmogorov complexity to measure difficulty of problems? REFFILE. I need to convert the values of packed decimal fields in itab to numeric type. What sort of strategies would a medieval military use against a fantasy giant? This test case will show the process for converting a binary numeric format to an edited numeric format. And each numeric number takes 4 bits to represents themself. is there any way to fix this issue without making use of another variables (e.g. For most numeric processes, RPG implicitly converts numeric values to packed decimal format before processing them. This program (NBRCVTC1.cbl) was written to show various techniques for converting between various Packed numeric field formats used on the mainframe and/or with the COBOL programming language. We have seen how to handle EBCDIC coded files This first patch isn't directly applicable to all the projects, but if this is approved then I have follow-on patches for gdb and binutils. Asking for help, clarification, or responding to other answers. Table 1. about its content to see if, for example the file contains binary zeros or something I just wanted to know, do we have any tool or utility through which we can do the same. for access to white papers, program examples and product information. Enter 2 and 3 in the TO section of the panel, for example:CA File Master Plus -- Reformat your.CONVERT.LIB(REFORMAT) COMMAND ===> SCROLL ===> CSR FROM Record ------------ CPYBK#O1 of your.CONVERT.LIB --------------Num Field Name Pos Format Row 1 of 3 1 DATAREC1OLD 1 78 2 FIELD1-PCK 1 P 8.2 3 FILLER 7 C 72 *************************** Bottom of Record Layout *************************** TO Record ------------ CPYBK#N1 of your.CONVERT.LIB --------------Num Field Name Pos Format Reformat Row 1 of 3 1 DATAREC1NEW 1 80 2 FIELD1-NUM 1 N 6.2 2 3 FILLER 9 C 72 3 *************************** Bottom of Record Layout ***************************After pressing enter the numbers will be automatically translated to the field names.Press PF3 and type E now.You will see the JCL now. Browse other questions tagged, Where developers & technologists share private knowledge with coworkers, Reach developers & technologists worldwide, How to convert Decimal Values to Strings in COBOL, How Intuit democratizes AI development across teams through reusability. No exact equivalent. and what would happen then? These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats. However, it occasionally shows up as a problem. A good place to start is When you write a packed field to a WORK file, the output record will contain the field in packed format. image will clarify things. download a sample text file. Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. Why would you get a truncated value? This assumes the string value is made up of 3 parts separated by spaces. Other uses will require a SimoTime Software License. You are right, the issue is in that definition. Move packed field to X (05) (here I got value as x'0123450000') Converting packed to string:-. And then, do the calculation with WS-NUMBER. Although some programmers prefer to define numeric columns as zonedbecause it's easier to print or view the raw data in this formatthe computer works more efficiently with numbers stored in packed decimal format. We have made a significant effort to ensure the documents and software technologies are correct and accurate. about the data types just in case you dont know about Cobols syntax. The Result field is also defined with a SIGN TRAILING SEPARATE that creates an additional byte to the field for the sign. The following (nbrcvts2.sh) is the Bash Shell Script needed to run this job on a Linux or UNIX System using GnuCOBOL. the COBOL Routine for Example-102 we must set the TextQualified option to False. The Source Field is defined as a Packed (or COMP-3) and the result fields are "USAGE IS DISPLAY" or a numeric edited field. The following PROCEDURE DIVISION statement shows how to convert from a PACKED to a DISPLAY (or unsigned Zoned-Decimal) numeric value. The Zoned-Decimal format may be used as the result field of a conversion process, for COBOL this is explicitly coded or defaulted as "USAGE IS DISPLAY". Please suggest. At the end of the exercise variable Y contains something that is readable and makes sense to the normal human eye. To learn more, see our tips on writing great answers. The following is a flowchart of the job for executing the programs that show the conversion between the various numeric field types. The next image should clarify the steps to follow. Packed-decimal format means that each byte of storage (except for the low order byte) can contain two decimal numbers. In the world of programming there are many ways to solve a problem. This is also true for external decimal (DISPLAY and NATIONAL) types that are converted by the compiler to packed decimal for COMPUTE statements. How would "dark matter", subject only to gravity, behave? the COBOL Routine for Example-204 Use DECIMAL ( i + d, d) or NUMERIC ( i + d, d) If a host variable includes an indicator variable, the SQLTYPE value is the base . can be converted to numeric values via File Master using COBOL copybooks. I HAVE A PACKED DECIMAL FIELD WHICH IS REDEFINED TO A NUMERIC FIELD TO ADD "1" TO ITS TENTH DIGIT. The following is the Bash Shell Scripts required to run the jobs on a Linux or UNIX System. and view the COBOL source code for this numeric field conversion example. How to convert 'PD' to 'ZD'. and view the COBOL source code for this numeric field conversion example. Hope you could figure out. > We need to convert this hex character to its decimal equivalent. I am unsure of the correct interpretation of the following field definitions and was hoping someone would know: FIELD-NAME-1 PIC S9(15)V9(3) COMP-3. For detailed information on DFSORT's numeric conversion parameters, see z/OS DFSORT Application Programming Guide. :http://www.microsoft.com/en-us/download/details.aspx?id=20397. Site design / logo 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA. As both REDEFINES occupy the full 15 bytes, there is no need to take account of any value in Y prior to the MOVEs to T or U. The low-order byte contains one digit in the leftmost portion and the sign (positive or negative) in the rightmost portion. Sorry I am two years late :-( . Moving packed-decimal (PIC S9(11)V99 COMP-3) to zoned-decimal (PIC S9(11)V99) is completely valid - providing the comp-3 data is properly signed numeric. previous tip about importing mainframe data, you will remember that the Visual on the properties frame set to true the UseBinaryFormat property. For your program, check for negative (D) and if not, treat as positive. and view the COBOL source code for this numeric field conversion example. REFFILE.
Go2bank Ach Transfer Limit, Vegan Birthday Cake Marks And Spencer, Barratt Homes Reservation Fee, Wyoming Behavioral Institute: Hospital Of Horror, Articles H