Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. Reinstall and add new DE powder. Thanks for the schema!! My pump & filter are Haywards. Terrible storms 2 nights ago. Ive checked out your blog and you had very good info for audience. $8.99 $5.99 As low as $4.49 Dow Corning - Molykote 111 6 gram O-ring Silicone Lubricant and Sealant - Be sure to lube your O-rings to help prevent leaks. IF thats good, check the pipe coming into the pump, does it drip when the pump is off? One washer on each side of the spring, you are correct. Sometimes pump lids can also warp or even the pump housing or internals, in cases where the pump got REALLY hot, but that is rare, but if the cause, youd need some new parts, or new pump. The breakers still seem to be working since when I turn the breaker on and the timer switch for the pump, it does send power to the pump. Should it be very hot to touch or is this an indicator for a capacitor problem? dual-speed pool pump. I have 2 extension cords running to plug it in. I found the switch to turn off the capacitor was not operating correctly. My hayward powerflo matrix 1.5hp pump doesnt turn on after working fine the whole month of June. "As for cleaning the pool filters, I do this every couple of days and doesn't help pressure.". I added new wire and plug end but when I plug it in it trips the breaker. I am very sure the water comes from underneath, not from plumbing fitting threads. I turned the gas off to it. It did not do this until we pressure washer the deck and some wood chips got into the pool. No air leaks and it only does this as the heater warms the water up during hot days. Could be a change in vibration, press down on the pump, to see if the tone changes. Its less than 2 wks old. Do you think its the capacitor and I can get another one from Hayward, or possibly mis-wiring? Thanks. Then, take a look at the capacitor, located at 9 oclock. If you suspect your breaker has broken, call a certified electrician to further diagnose the problem. 5. We replaced fhe shaft seal but the pump doesnt pull any water in there is no suction. If low flow is not caused by a clogged strainer, inspect the cleaner hose for pressure loss (leaks). From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. Changed lid gasket and plugs in basket still same issue. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). This code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. Press and hold the diagnostic button for 3 to 5 seconds. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. Any idea how to correct this. Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. But just like any sort of equipment, even the most well-made products sometimes need repairs. The new pump then starts to overheat and it shuts off. Rust can develop inside the motor that you can break free, by spinning the shaft a few times. If thats all ok, you may want to shut off the isolation vales, and remove the handle and lid from the multiport valve and inspect the spider gasket. Entire pump system with pump basket and housing. Thanks. This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. It ran all night and still going. Davy, In some instances, it could just be a bad breaker. Hi Jim, sounds like an air leak, or low water in the pool, or a stuck skimmer weir blocking water flow into the skimmer. I believe you must have some type of switch, for code cant just wire it directly to the breaker. I checked the power to the timer and I have 120 v to L1 & L2 but timer not running & pump wont run when I turn pump on manually. Hi Toula, consider that the impeller may be clogged, or you may have an air leak, in front of the impeller. Have a Hayward variable that was replaced last year. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. It had a non Hayward motor installed before. I opened my pool this weekend and started the pump and let it run for few hours before stopping it. second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. Hi Carlos, sounds normal. After cleaning the pool the pool pump would just hum and not start. Contact a professional for further assistance. Packing Pool Putty or Silicone around the fitting is a good fix, replacing the fitting is a better fix. Anything else to fiddle with or bad motor? Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? When tablets are used in the skimmers, Flex pipe beneath the skimmer can swell inside and begin to crimp and close (over many years time), so that a small amount of debris can clog the line. Returns are getting good supply, the gauge on filter is bouncing up and down. Ive tried setting up the vacuum with power on and power off and its no different. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? Shut off the valves or plug the skimmer and return, so you can keep the water in the pool while you get it sealed up. It will start to run normal for 2-3 seconds. Could be too big for the pipe size, although normally I would think that a 1hp should be fine, but do a wheel RPM test on the cleaner (28-32 RPM of the wheel is ideal), and bleed off excess water pressure at the wall fitting. If so, it will always read 100%. I have a Hayward super flo matrix pump. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. The wire size may depend on the distance of wire run. Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. BLUE-ESSENCE-20 20K GAL SALT CHLORINATION SYSTEM (HAY-45-0020) Product # : HAY-45-0020 Mfg : HAYWARD POOL PRODUCTS INC Mfg # : BLUE-ESSENCE-20 (FLORIDA ONLY) Department : FEEDERS | CHLORINATORS | SANTIZERS Product Line : Salt Generators UOM ( Default ) : EA Obsolete : This product is not obsolete. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? it will not pull up off the pump basket. What is the problem. Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. I disconnected it and plugged the Aquatrol in alone; that worked fine. Pumps, Learn About IF its a broken off grease cap, tap in a sharp screwdriver into where it threads in, to get some bite, and then slowly and firmly back out the broken off threaded connector, turning CCW, then replace with a new Grease Cap, or a 1/8 threaded plug. It should be the receiving 115V or 230V, depending on how it is wired, plus/minus 10%. If the pump plugs into an outlet, I would check the GFCI button to be sure the outlet has not popped or tripped. Rob, the air leak is coming from the pump, or before the pump. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. I made sure the basket was seated properly and put grease on the o-ring on the cover and made sure it was tight. Better call an electrician for that though, 2 speed Hayward pool pump motor is very loud only when on high speed. Seemed to be operating fine and I was vacuuming pool and lost suction. 12 ga or 14 ga? Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. Move switch to center position and adjust dial to a percentage that you think it needs. HI Sang, check the capacitor, or just replace it, they are cheap, it is the large black cylinder at 9 oclock in the rear of the motor. If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. A very thin layer of rust develops between the stator and the rotor inside the motor, and getting a 7/16 open end wrench on the end of the shaft, and working it back and forth, breaks the rust and frees up the shaft to spin. Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. Maybe the GFCI button tripped? If your pool pump is not pumping water, check that all suction and return valves are open, and the pump lid is on tight, with the lid o-ring in place. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. For some time now I have been pushing along with my old cell (t-9 model). Just put he new motor on and its still not working, sounds like power is being sent to the motor, but nothing. Then recharge with a good dose of DE powder. Don't stress! Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. Went out today to find the lower plastic shroud melting again? Currently it is at pool level. Learn more about pool care and repair. We have a sand filter and no pressure gage. When I turned off the pump I saw that it spit a little bit of water out of a Jandy Valve. Could be a problem with the centrifugal switch, located dead center on the rear of the motor, or the stationary switch, located beneath it, and contacting each other in the center. Its linked to an AutoChlor switcher and comes on twice a day but failed to switch on a couple of days ago. ), 3) the pump drain plugs (tight and Teflon tape used? At first, the pump would only hum and not work. It appears to be stuck. Any idea why I would be drawing more current? Quite a criticism for something costing 33bn-plus. Use jumper wire to jump TH terminals. The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. I had to have a pool person come out & they got me good. The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. If you find out, I would check the owners manual for information related to your symptoms. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. Replaced motor and seal on my Hayward Northstar. . "@type": "Organization",
Nothing is making any noise now and pump is not working at all. Hi Julie, is the FLO error code on the heater? All Rights Reserved. This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. I have a blue essense 20,000 salt system and can find very little online. i have a 4 wire set up, ground, line , low speed,high , just want to make sure i wire correctly, 1- line 1, 2- high speed, 3or4 to low speed? Hi Rodney, well the Green wire should be ground, so that eliminates one choice. This morning I decided to open fully all valves while pump was on low and no flow was detected. bought a SP2610x152s super pool pump 1.5 hp. $579 + Free Shipping in USA. Today two years later, same company opened pool,pump stuck and want to install another 3400vsp for $1330. Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. Remember also with DE powder, it is half-weight of other dry measure, so if instructions say 5 lbs of DE powder, thats not 10 8-oz cups of dry measure (kitchen measure), its actually double that, or 10 lbs, if you were using a 1-cup measure. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Hi Cindy, most likely an air leak. If symptoms continues with the filter on recirculate, you would have different problems, like restriction or obstruction in the pipes. With the information explained in this comprehensive troubleshooting guide, you can diagnose and repair your Hayward single speed or variable speed pool pump with ease! Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? Hi David, impellers that have signs of wear are usually operating without a problem. it runs Happens all the time to pool pumps, and the way to un-stick it is to do some disassembly in the rear of the motor, to get a wrench on the slotted rear of the motor shaft, and work the shaft back and forth for a minute, to break the rust seal, and get the shaft to turn again. If no, test power on the wires coming into the pump, place test meter leads on the red and black wires, with power turned on to the pump. If the next day the chlorine level is nearly zero, shock again. The pump is 18 yrs. It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. Any insight would be helpful. Capacitor or needs new motor?? Then check the GFCI for loose wires. Any thoughts? Probably not a pump or motor problem (but could be). If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. Most heaters can operate on 120V/240V, either one. if this is installed below pool water level, also close the isolation valves, to keep the water in the pool, and avoid soaking your socks! Troubleshooting Guides; Troubleshooting Guides. Double check that connections are snug and fitted properly. Probably not your pump basket being full causing this but improper air flow caused by debris/dust. Maybe you could just wire the pump directly to the breaker? I have it set to run for 3 hours in low speed and 5 in high. I owe you a beer if you are ever around my neck of the woods. "url": "https://intheswim.com/",
Mt Tercer nivel ( dos elevadores ) 3 recamaras, Depto: 4 recamaras Salita de visitas Salita de TV 2, Diseado por travel organiser personalised. Ive never owned a pool before and didnt have any problems all summer until the last 2 weeks. Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. I have this same Drive Error Message. If the backwash line continues to leak, remove the multiport valve lid and inspect the spider gasket for wear or damage in the waste port area. No leaks, pressure is good, suction is good, connections seem right. There is also a faint burnt odor. Step 3: Double check the wires on the flow switch for damage. Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. I have a Hayward Perflex DE filter brand new last year. And you cant rule out a problem with the circuit board either. i have a hayward 240 super pump, which have had for about 10 years. Hi Tammy, could be many things. You may be able to remove the basket and reach thru the volute to the eye of the impeller, and may be able to feel debris. Superpump lid gaskets are a square cut gasket that can come out of the groove easily, be sure it is seated properly, and lube it with Teflon pool lube regularly. Are you using DE powder or enough DE powder? GFCIs are sensitive, but for a reason. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. Lets see what we can do It is a common problem with Hayward Perflex, the symptoms you describe, and is usually clogged fingers. Perflex filters are particularly known (to me anyway) for building up oily deposits on the fingers or flex tubes, and clogging up quickly. Hi Damon, I would suspect the chattering sound to be a loose stationary switch and/or centrifugal switch on the motor, in the rear of the motor, remove the cover and look for something amiss. Its a Hayward self-priming Super Pump. Then the others are 2-high speed and 1-low speed wire see the diagram on this page: http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html. All switch in the center. You have both filter pump and polaris pump on one timer? Signs of wear under the wear ring is normal, and it should be pumping normally. Not the power leads, but other connecting wires from the terminal board to the switch, to the cap? My pump, when in the normal running position, leaks water in a slow steady flow out the tubing used for backwashing. Sometimes this can be cleared or removed, without pulling the pump apart, which is def. any advise would be appreciated . Is the motor still good. If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. Other timers will have a different switch, but all should have someway to override. (PUMP and RETURN pipes). But now Im trying to plug it in and it doesnt make any noise at all. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. If it is new, you may have undersized the cell, or your water chemistry is imbalanced, preventing the chlorine from working efficiently and effectively. Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. Replace with the exact same MFD number, printed on the capacitor. Third, is there a valve closed after the filter, or some other obstruction? Of course, be sure the pool water level is good, and the skimmer weir door is not stuck, or blocking water flow into a skimmer. They are easily replaceable. Its not raw gas, but a sour smell. Could be insects or the copper arms are bent, or something caught up in the works, This is usually directly in the center of the motor a centrifugal switch, steel with side springs, and a triangular shaped switch attached at 6 oclock, but contacting the cent. What would have caused this? Flush out the housing to clear debris, then refill with water. Use a multimeter on the AC volt setting of 240V, and place the meter leads on the wires on the time clock. Hopefully the GFI then holds. Any thoughts? how to watch past broadcasts on twitch. The electrician also installed w new capacitors on the pump and still same problem. I have perhaps a really basic question I just cannot get one side of my salt cell to seal with the union. Though it is a different control, they use the same cell; so if you are getting a temperature reading of 215, you need to replace the cell. You should also check for loose, crimped or broken wires or rusty terminals on the capacitor. Could be the use of a clarifier or flocculent that is clogging the sand? Pull out on the dial, and reset it, until you feel the gears engage. Has more of an impeller type sound. At a total loss here, any suggestions would be greatly appreciated. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. A sticky skimmer weir door can cause water blockage to the skimmer, and give priming problems too. Any ideas? I just purchased a pool home that is utilizing a Hayward Northstar SP4020NS I have noticed that when the pump shuts off water briefly blows out of the strainer cover, like a pressure release. Your options are to 1). Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. 2017). The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. Hi Thomas, the fitting that goes into the pump, was it also replaced? Any suggestions. Also check the threaded pipe that comes into the pump, #1 most common air leak. Im very new to pools & pool maintenance in general. Weve not had this issue the past 2 years (we bought the house 2 years ago). Do you have any advice? Soak in TSP for an hour, and in the acid for 10 minutes. replace the entire pump with exact replacement. 2 year warranty. But first, remove the fingers again, and soak the entire Nest Assembly in a bucket filled with pool filter cleaner, to dissolve oils and scale. Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. Im not sure how the filters went bad being winterized, but they were way old. Get support by contacting us online, hayward With the pump off, remove the basket and reach your hand back into the eye of the impeller. Sometimes its the filter that is drawing in air, thru the air bleeder or clamp band or bulkhead, which causes the filter to drain out through the pump, and back to the pool. I recently noticed what appears to be a shaft seal leak. Hi Mike, after backwashing a DE filter, you need to add DE filter powder again. So i contacted them and waiting for response but tempted to just get another replacement to keep circulation in pool because i just drained and refilled pool 5 days ago and running a waterfall pump to get some circulation and watching chlorine level. I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. Breville Tamper Coffee Kit 54mm, Look for any small drips or oozing around the filter, or you may be able to hear a small hiss, when the pump shuts off. A pool guy who has since stopped operating put it in. After coming across that it would no longer produce chlorine after 6 years, I decided to buy a new cell. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. Replaced battery on top of pump cover and still nothing??? look for a hi-voltage/low-voltage diagram on the motor label. Your 1 hp Hayward Superpump can pump 75 gallons per minute, which is too much flow for most AG pool filters. Hi Vandee, By default the selector plug is in the 230V position, but in rare cases like yours, it may come mis-aligned or mis-attached from the factory, and need to be shifted. Could the filter be plumbed backwards possibly? https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. Blocked air vents and no air flow is also a possibility. But the moment the basket fills with water its like the pump just kicks down to barely running or humming at all. I next realized the shaft (impellers) was frozen, and was able to free it up so it now spins smoothly. "logo": {
Hi Dave, check the owners manual to be sure that the cord size used is proper for the motor, and the plug, is a 3-prong grounded plug? i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . If you have a time clock or light switch in addition to the breaker, Id recommend using that to turn pump on/off, rather than the breaker. Hi Joe, I would first suspect an air leak, Superpumps can also draw air from a loose drain plug and easily around the square lid gasket but the usual suspect is the pipe coming into the pump. Thanks, Steve DeGray. As you found, if the motor sounds just as loud when it is pulled out or removed from the pump housing its usually the bearings, which normally last for up to 10 years, not in this case it seems. And that the top gasket seats well into the groove in the filter body before putting the lid on. But most likely an air leak, either before or after the pump, pool systems are supposed to be mostly air tight, though most are not completely. Then check power (volts) coming into motor to verify and if it still wont come on (and makes no attempt to) its likely dead. If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, Big difference, but other than that, they operate pretty much the same!
International Scout For Sale Craigslist Alabama,
Property To Rent Eastbourne,
Marjorie Hill Obituary,
Suburb Profile Bayswater,
Articles H